- Is there any limitation on the input signal format when trying to convert Single Link to Dual Link (by MUX function)?
Products FAQ
SupportProducts FAQIs there any limitation on the input signal format when trying to convert Single Link to Dual Link (by MUX function)?
UsageV-by-One HS・LVDS
Both DE=Low and DE=High periods should have even pixel width. If any odd pixel width is entered, the data may be changed or the clock’s duty cycle may be modified, depending on products.